Saturday, October 10, 2020

Publication: Label-free imaging of cancer spheroid dynamics

 Our colleague Ibrahim Abd El-Sadek recently published his new technology "dynamics optical coherence tomography OCT imaging." In this study, he demonstrated new imaging method, which is a combination of new imaging protocol of OCT and a newly developed signal processing method. 

By using this method, he successfully visualized the tissue activity of human cancer culture (MCF7 spheroid) totally non-invasively. This method also successfully visualized the anti-cancer drug response of the MCF7 spheroid.

The details are reported in Biomedical Optics Express, a journal of Optical Society of America.

>> Full length article (open access).

The digest of this research is also available on this short presentation video (YouTube).


私達の研究室の博士課程在学中の Ibrahim Abd El-Sadek さんが組織ダイナミクスイメージングに関する論文を発表しました。この研究で Ibrahim さんは新たに「組織の活動性を非侵襲・ラベルフリーにイメージングする手法」を開発しました。これは、OCTの新しい走査法とOCT信号の時間ゆらぎを解析する新しい信号処理手法の組み合わせによって実現されています。

この手法により、ヒト乳がん由来の培養組織(細胞凝集体)内部の代謝や壊死の様子の可視化に成功しました。また、この培養組織の抗がん剤に対する薬剤反応の可視化も可能になりました。

詳細は米光学会の学術雑誌 Biomedical Optics Express に発表されています。

>> Full length article (open access).

この研究のダイジェストはこのプレゼンテーション ビデオ(YouTube) でもご覧いただけます。

Citation:
I.A. El-Sadek, A. Miyazawa, L.T.W.Shen, S. Makita, S. Fukuda, T. Yamashita, Y. Oka, P. Mukherjee, S. Matsusaka, T. Oshika, H. Kano, and Y. Yasuno, "Optical coherence tomography-based tissue dynamics imaging for longitudinal and drug response evaluation of tumor spheroids," Biomedical Optics Express 11, 6231- (2020).

Thursday, October 1, 2020

Publication: Phase stabilization for holographic OCT processing

Our colleague Kensuke Oikawa recently reported a newly developed numerical method for volumetric phase stabilization of optical coherence microscopy (OCM) in Biomedical Optics Express.

In this study, Kensuke developed a new method to estimate the volumetric phase error (bulk phase error) of OCM, and also developed a method to correct this error. This method enabled highly accurate holographic processing of OCT.

By using this method, he demonstrated holographic refocusing of volumetric OCM of muscle samples. Owing to this methods, the fine muscle fiber structure was visualized over more than 600-um depth.

The details of the research is reported in Biomedical Optics Express.

>> Full length article (open access).


当研究室の及川健介君が研究成果を Biomedical Optics Express 誌に発表しました。
 ここで新たに開発された手法は、三次元OCT顕微鏡(OCM)のデータにおける位相誤差を推定し、さらにそれを補正するものです。この位相補正により、OCMデータにホログラフィー処理を適用してその画質を向上することが可能になりました。
 論文の中では、実際に「ホログラフィック・リフォーカス」と呼ばれる処理を用いることで、三次元のOCMデータの全深さ領域におけるフォーカスずれの補正を行いました。これにより、深さ600ミクロンい所の範囲で生体試料の微細な筋繊維が可視化されました。

この研究の詳細は Biomedical Optics Express 誌に掲載されています。

K. Oikawa, D. Oida, S. Makita, Y. Yasuno, "Bulk-phase-error correction for phase-sensitive signal processing of optical coherence tomography,"  Biomedical Optics Express 11, 5886- (2020).